Hi Faouzi,
I do not know if you mean option "Q" in TH1::Fit or what.
The option "Q" in TH1::Fit sets the following Minuit options:
double arglist = 0;
gMinuit->mnexcm("SET NOWarnings",&arglist,1,..
arglist = -1;
gMinuit->mnexcm("SET PRint",&arglist,1,..
When using this option "Q", you should not get any printout at all.
Rene Brun
On Mon, 19 Jun 2000, Faouzi Attallah wrote:
> Hi Rene,
>
> When fitting one can turn-off the warnings and printout via
> fit option Q
> and gMinuit->mnexcm("SET NOW", &nbr, 1, i);
> or nbr = -1 ; gMinuit->mnexcm("SET PRI", &nbr, 1, i);
> Despite this I still getting the following message :
> FUNCTION MUST BE MINIMIZED BEFORE CALLING MINOs
> is there anyway to get rid of this when the QUiET mode is called.
> (I have more than 400 fits/spectrum, and a considerable amount of spectra each
> time).
>
> Thanks a lot.
> Faouzi
>
> Dr. F. Attallah
> GSI mbH
> Planckstr 1
> D-64291 Darmstadt
> Tel: +49 (0)6159 71 2743
> Fax: +49 (0)6159 71 2901
> Email: F.Attallah@gsi.de
>
This archive was generated by hypermail 2b29 : Tue Jan 02 2001 - 11:50:28 MET